Guangdong, China
Business Type:
Manufacturer/Factory & Trading Company
Number of Employees:
12
Year of Establishment:
2016-01-26
Plant Area:
500 square meters
Average Lead Time:
Peak season lead time: within 15 workdays
Off season lead time: within 15 workdays
OEM/ODM Service
Sample Available

Dental Handpiece, Dental Product, Dental Equipment manufacturer / supplier in China, offering Good Price Set of Contains Low Speed Motor Contra Angle Head Straight Head Handpiece, Dental Teeth Model Denture Dental Caries Model, Dental Caries Model and so on.

Diamond Member Since 2019
Audited Supplier
Supplier Homepage Products Dental Handpiece Others Dental Handpiece Good Price Set of Contains Low Speed Motor Contra Angle Head Straight Head Handpiece

Good Price Set of Contains Low Speed Motor Contra Angle Head Straight Head Handpiece

Get Latest Price
Min. Order: 2 Pieces
Port: Guangzhou, China
Production Capacity: 50000pieces/Year
Payment Terms: T/T, Western Union, Paypal
Condition: New
Certification: ISO9001, ISO, CE
Material: Stainless Steel
Light Way: With LED Light
Water Way: Inner Channel
Usage Times: Non-Disposable

You Might Also Like

Loading...

Basic Info

Model NO.
Xh002-5
Application
Adult
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Internal Exhaust
Number of Holes
Two Holes
Connection
With Quick Connector
Rotating Speed
Low-Speed Handpiece
Trademark
STARXH
Transport Package
Box
Origin
China
HS Code
90184990
Good Price Set of Contains Low Speed Motor Contra Angle Head Straight Head Handpiece

Good Price Set of Contains Low Speed Motor Contra Angle Head Straight Head Handpiece
Good Price Set of Contains Low Speed Motor Contra Angle Head Straight Head Handpiece
Good Price Set of Contains Low Speed Motor Contra Angle Head Straight Head Handpiece

Contra angle
Operation manual
 
Caution
·Read this Operational Manual before use to fully understand the product functions and file for future reference.
·When operating the product always consider the safety of the patient.
·Check for vibration, noise and overheating outside the patient's oral cavity before use.
If any abnormalities are found, stop using the handpiece immediately and contact dealer.
·Users are responsible for the operational control, maintenance and continual inspection of this product.
·Do not attempt to disassemble the handpiece or tamper with the mechanism.
·Do not connect or disconnect the handpiece or bur until the drive motor has completely stopped.
·Perators and all others in the area must wear eye protection and a mask when operating this handpiece.
·Depressing the push button while the handpiece is in operation may cause overheating, serious technical damage and possible premature handpiece failure. During operation avoid contact with any oral tissue that may cause the push button to be depressed while the handpiece is in operation.
·Do not use high acid water or sterilizing solutions to wipe, immerse or clean the product.
·The products are delivered in a non-sterile condition and must be sterilized prior to use.
·Always keep the bur/drill shank clean. Debris in the chuck mechanism can prevent burs from seating properly and cause them to fly out during use.
·Perform regular function and maintenance checks.
·If the product is not used for a long period check it is functioning correctly before using on a patient.
·To avoid clinical downtime it is recommended that a spare be kept on hand in case of a breakdown during surgery.
·20:1handpiece Always operate with water spray failure to do
So may result in overheating.
·1:5handpiece Do not start the handpiece without the bur installed, can cause the head overheating or damage to the cartridge.
·Do not operate the handpiece without the bur/drill.
·Do not connect or disconnect the handpiece until the handpiece until the motor has completely stopped.
·Do not immerse handpiece in any chemical solvent or solution or dry-heat disinfection. Sterilization by autoclave at (135ºC&0.22MPa) is suggested.
 
Users and Intended Use
User:Qualified Professionals
Indication For Use:This medical device is intended for transmitting rotation of the power source at the direct drive ratio or at a different gear ratio, thereby running the instrument such as a bur or a reamer to cut and polish natural or artificial teeth during dental treatment.
 
Connecting/Disconnecting handpiece and motor
AttentionGlass rod optical handpiece pin, alignment the motor groove.
·Do not connect or disconnect the handpiece until the handpiece until the motor has completely stopped.
·Use only good condition cut shank in line with standard grinding bur.
·When the collect switch is open or the bur is not inserted, don't start the motor.
·After the bur/drill is located in place, lightly pull out the bur/drill to make sure the bur/drill is located.
·If the bur/drill does not install firmly, it may fly away or it does not remove.
 
Checking the handpiece before each use
Follow the check procedure below before use. If any abnormalities are found, stop using the handpiece immediately and contact your dealer.
  1. Check the head cap or cap is firmly tightened.
  2. Insert the bur/file
  3. Rotate the handpiece for about one minute at the max rotation speed of the attached motor. During rotation, check for abnormalities such as abnormal rotation vibration.
  4. After the handpiece rotation has completely stopped, touch the handpiece head to confirm the head is not heating abnormally.
 
Maintenance
1. Cleaning
Caution:
·When handpiece clean dirt of external surface be careful the water does not enter into inside of rear of the handpiece.
·1:5handpiece Installation of the bur, immersed in water rotation cleaning.
·If the dirt could not be removed from the hole, clean it by brush.
·Remove debris from the product. Do not use a wire rush.
·After the treatment of each patient, clean the head.
 
  1. Remove bur/drill from the handpiece.
  2. Remove any debris in and around the outlet holes with the brush.
  3. Half fill a cup with clean water. Operate the handpiece about 15 seconds, and immerse 20mm of the handpiece head in the water.
  4. Lubricate before autoclaving.
 
Spray nozzle cleaning
  1. Clean internal spray nozzle and external spray nozzle (internal and external) by using cleaning wire.
  2. Insert a irrigation tube in each spray nozzle, and wash it away with clean water.
 
Cleaning the glass rod optic
Cleaning the glass rod optic and LED with cotton swab soaked in alcohol.
Caution:
·Do not use a pointed tool for sharp edged to clean the glass rod optic and the LED. They may damage the mirror finish and reduce the light transmission efficiency.
·optic end and LED has become damaged return it to dealer for repair.
 
Lubrication
  1. Disconnect the handle from the motor.
  2. Remove the bur from the handpiece.
  3. Mount the tip nozzle into the spray can port.
  4. Insert the tip nozzle into the drive air port of the handpiece. Hold the handpiece and spray for approximately 2-3 seconds. Apply lubricant until it expels from the handpiece head for at least 2 seconds.
  5. Cartridge should be maintained. It is necessary to remember lubrication cleaning, place the residual impurities, rust bearings.
Sterilization
All handpieces can be autoclavable up to Max.135ºC.
  1. Scrub dirt and debris from the handpiece, and wipe clean with alcohol-immersed cotton swab or cloth. Do not use a wire brush.
  2. Insert into an autoclave pouch. Seal the pouch.
  3. Autoclave up to Max.135ºC.
    Autoclave for 20 mins.at 121ºC, or 15mins. at132ºC.
  4. Keep the handpiece in the autoclave pouch to keep it clean until you use it.
 
Caution:
·Do not wash soak, or wipe off the handpiece within the oxidation potential solution (strong acid/super acid solution) or sterilized solution.
·Do not autoclave the equipment which with residual chemical. It may cause a peel off the plating or exert a harmful influence to internal parts.
·Store it in a place where the handpiece is not subject to air with dust, sulfur or salinity.
·Do not touch the handpiece just after the autoclave. It is extremely hot.
Operating temperature:+10 - +40ºC operating humidity:80%RH
Storage temperature:+10 - +55ºC storage humidity:93%RH
 
Trouble shooting
TroublePossible causeSolution
Body of straight head or Contra angle rotates during motor runningO-ring on the nose of motor wearsChange o-ring
Handpiece fail to rotateContra angle chucking with bur but latch plate fail to be fixed in the proper position. Dirt gets into the handpiece.Clean and lubricate , move it by hand
Our service center can offer technical assistance to you.
 
Warranty
Maintenance over the term of guarantee will be at the customer's charge. Our company will not be the responsible for damage or injury resulting from:
----excessive use
----improper manipulation of the product, or modification to product carried out by persons not authorized by our company.
----fail to follow the instruction to install, operate and maintain the handpiece.
----damage of chemical, electrical or electrolysis due to improper autoclaving and storing
----improper working pressure
 
The technical specifications and dimension in these instructions are given only as a guide. They may not be subject of any claim.
 